HB FULLER FH-5313-A
Flammability | 1 | |
Toxicity | 2 | |
Body Contact | 2 | |
Reactivity | 1 | |
Chronic | 2 | |
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4 |
Part A or Base of a 2 pack epoxy adhesive. Requires that the two parts be mixed by hand or
mixer before use, in accordance with manufacturers directions. Mix only as much as is
required. Do not return the mixed material to the original containers.
"2 part Epoxy Resin Part A"
May cause SENSITIZATION by skin contact.
Limited evidence of a carcinogenic effect.
Possible risk of impaired fertility.
Possible risk of irreversible effects.
Harmful by inhalation, in contact with skin and if swallowed.
Irritating to eyes and skin.
Toxic to aquatic organisms, may cause long- term adverse effects in the aquatic
environment.
Accidental ingestion of the material may be harmful; animal experiments indicate that ingestion of less than 150 gram may be fatal or may produce serious damage to the health of the individual. Considered an unlikely route of entry in commercial/industrial environments. Ingestion may result in nausea, abdominal irritation, pain and vomiting.
This material can cause eye irritation and damage in some persons. The liquid may produce eye discomfort and is capable of causing temporary impairment of vision and/or transient eye inflammation, ulceration. The material may produce moderate eye irritation leading to inflammation. Repeated or prolonged exposure to irritants may produce conjunctivitis.
Skin contact with the material may be harmful; systemic effects may resultfollowing absorption. This material can cause inflammation of the skin oncontact in some persons. Epoxy materials may cause allergic and/or contact dermatitis responses, which may occur on exposure or may become apparent only after repeated exposures. Sensitization is possible. Photoallergic dermatitis may result from contact with the material. This type of response can be elicited only in individuals who have been previously allergically sensitized to the chemical agent and appropriate radiation. Photoallergic dermatitis presents, clinically, as an eczematous dermatitis in sun-exposed areas. Sensitization may result in allergic dermatitis responses includingrash, itching, hives or swelling of extremities. Sensitization reactions may appear suddenly after repeatedsymptom free exposures. Open cuts, abraded or irritated skin should not be exposed to this material. The material may accentuate any pre-existing skin condition.
The material is not thought to produce respiratory irritation (as classified using animal models). Nevertheless inhalation of the material, especially for prolonged periods, may produce respiratory discomfort and occasionally, distress. Inhalation hazard is increased at higher temperatures. Inhalation of vapor may result in nausea, headache. Inhalation of vapor may aggravate a pre-existing respiratory condition such as asthma, bronchitis, emphysema.
There has been concern that this material can cause cancer or mutations, but there is not enough data to make an assessment. Skin contact with the material is more likely to cause a sensitization reaction in some persons compared to the general population.
Primary route of exposure is usually by skin contact with the material. Prolonged or repeated skin contact may cause drying with cracking,irritation and possible dermatitis following. Sensitization may give severe responses to very low levels of exposure, i.e. hypersensitivity. Sensitized persons should not be allowed to work in situations where exposure may occur. As with any chemical product, contact with unprotected bare skin; inhalation of vapor, mist or dust in work place atmosphere; or ingestion in any form, should be avoided by observing good occupational work practice.