VANTICO HARDENER HY 956
Flammability | 1 | |
Toxicity | 2 | |
Body Contact | 3 | |
Reactivity | 1 | |
Chronic | 3 | |
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4 |
Hardener or Part B of a 2 pack epoxy system. Requires that the two parts be mixed by hand
or mixer before use, in accordance with manufacturers directions. Mix only as much as is
required. Do not return the mixed material to the original containers. Applied using a
hand trowel or spreader.
"epoxy resin hardener curing agent"
Harmful in contact with skin.
Causes burns.
Risk of serious damage to eyes.
May cause SENSITIZATION by skin contact.
May cause harm to the unborn child.
Harmful to aquatic organisms, may cause long- term adverse effects in the
aquatic environment.
The material can produce chemical burns within the oral cavity and gastrointestinal tract following ingestion. Considered an unlikely route of entry in commercial/industrial environments. Ingestion may result in nausea, abdominal irritation, pain and vomiting.
The material can produce chemical burns to the eye following direct contact. Vapors or mists may be extremely irritating. If applied to the eyes, this material causes severe eye damage. The material may produce severe irritation to the eye causing pronounced inflammation. Repeated or prolonged exposure to irritants may produce conjunctivitis.
Skin contact with the material may be harmful; systemic effects may resultfollowing absorption. The material can produce chemical burns following direct contactwith the skin. Amine adducts have much reduced volatility and are less irritating to the skin and eyes than amine hardeners. However commercial amine adducts may contain a percentage of unreacted amine and all unnecessary contact should be avoided. Toxic effects may result from skin absorption. Sensitization may result in allergic dermatitis responses includingrash, itching, hives or swelling of extremities. Bare unprotected skin should not be exposed to this material. The material may cause severe skin irritation after prolonged or repeated exposure and may produce on contact skin redness, swelling, the production of vesicles, scaling and thickening of the skin. Repeated exposures may produce severe ulceration. The material may accentuate any pre-existing skin condition. Amine epoxy-curing agents (hardeners) may produce primary skin irritation and sensitization dermatitis in predisposed individuals. Cutaneous reactions include erythema, intolerable itching and severe facial swelling. Blistering, with weeping of serous fluid, and crusting and scaling may also occur. Individuals exhibiting "amine dermatitis" may experience a dramatic reaction upon re-exposure to minute quantities. Highly sensitive persons may even react to cured resins containing trace amounts of unreacted amine hardener. Minute quantities of air-borne amine may precipitate intense dermatological symptoms in sensitive individuals. Prolonged or repeated exposure may produce tissue necrosis.
Inhalation may produce health damage*. If inhaled, this material can irritate the throat andlungs of some persons. Not normally a hazard due to non-volatile nature of product. Inhalation of vapor is more likely at higher than normal temperatures. Inhalation of vapor may result in nausea, headache. Inhalation of vapor may aggravate a pre-existing respiratory condition such as asthma, bronchitis, emphysema. Inhalation of epoxy resin amine hardeners (including polyamines and amine adducts) and may produce bronchospasm and coughing episodes lasting several days after cessation of the exposure. Even faint traces of these vapors may trigger an intense reaction in individuals showing "amine asthma". The literature records several instances of systemic intoxications following the use of amines in epoxy resin systems.
Skin contact with the material is more likely to cause a sensitization reaction in some persons compared to the general population. Ample evidence exists, from results in experimentation, that developmental disorders are directly caused by human exposure to the material.
Principal routes of exposure are usually by skin contact with the material and inhalation of vapor from the curing material. Prolonged or repeated skin contact may cause drying with cracking,irritation and possible dermatitis following. Sensitization reactions may appear suddenly after repeatedsymptom free exposures. As with any chemical product, contact with unprotected bare skin; inhalation of vapor, mist or dust in work place atmosphere; or ingestion in any form, should be avoided by observing good occupational work practice.