欢迎来到MSDS查询网--MSDS安全网
当前位置:MSDS安全网 -> 英文MSDS查询 -> UNASCO TEFLON FIBRE REINFORCED THREAD SEA MSDS报告
免费英文MSDS查询网站--MSDS安全网
UNASCO TEFLON FIBRE REINFORCED THREAD SEALI MSDS报告[下载][中文版]

Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME

UNASCO TEFLON FIBRE REINFORCED THREAD SEALING COMP.

NFPA

Flammability 0
Toxicity 0
Body Contact 0
Reactivity 0
Chronic 2
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4

PRODUCT USE

Sealing compound.

SYNONYMS

"sealing compound"

Section 2 - HAZARDS IDENTIFICATION

CANADIAN WHMIS SYMBOLS

EMERGENCY OVERVIEW

RISK

In use, may form flammable/ explosive vapor- air mixture.

POTENTIAL HEALTH EFFECTS

ACUTE HEALTH EFFECTS

SWALLOWED

  The material has NOT been classified as "harmful by ingestion". This is because of the lack of corroborating animal or human evidence. The material may still be damaging to the health of the individual, following ingestion, especially where pre-existing organ (e.g. liver, kidney) damage is evident. Present definitions of harmful or toxic substances are generally based on doses producing mortality (death) rather than those producing morbidity (disease, ill-health). Gastrointestinal tract discomfort may produce nausea and vomiting. In an occupational setting however, unintentional ingestion is not thought to be cause for concern.  

EYE

  Although the material is not thought to be an irritant, direct contact with the eye may produce transient discomfort characterized by tearing or conjunctival redness (as with windburn).  

SKIN

  The material is not thought to produce adverse health effects or skin irritation following contact (as classified using animal models). Nevertheless, good hygiene practice requires that exposure be kept to a minimum and that suitable gloves be used in an occupational setting.  Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may produce systemic injury with harmful effects. Examine the skin prior to the use of the material and ensure that any external damage is suitably protected.  

INHALED

  The material is not thought to produce adverse health effects or irritation of the respiratory tract (as classified using animal models). Nevertheless, good hygiene practice requires that exposure be kept to a minimum and that suitable control measures be used in an occupational setting.  Fumes from burning PTFE-containing materials are irritating to the upper respiratory tract and may be harmful if exposure is prolonged. When heated for a long time a very small amount of hydrogen fluoride, carbonyl fluoride and perfluoroisobutylene is generated. The higher the temperature the greater is the decomposition rate.  Symptoms of exposure to hydrogen fluoride and carbonyl fluoride include burning sensation,  cough, dizziness, headache, labored breathing, nausea, shortness of breathe, sore throat and vomiting. Symptoms may be delayed. These substances are corrosive to the eyes, skin and respiratory tract. Inhalation may produce lung oedema. Prolonged exposures may produce hypocalcaemia High exposures may be fatal. Medical observation is indicated in the event of such exposures.  Symptoms of exposure to perfluoroisobutylene include cough, shortness of breathe, sore throat. Symptoms may be delayed. Symptoms of lung oedema often do not manifest until a few hours have passed and may be aggravated by physical effort. Rest and medical observation are essential. Immediate administration of an appropriate spray, or by the doctor authorised by him/ her, should be considered.  Overheated or burnt PTFE evolves highly irritating and corrosive hydrogen fluoride gas with small amounts of highly toxic carbonyl fluoride. Polymer decomposition starts at 400 deg. C. with rapid degradation at 540 deg. C.. Decomposition products are complex.  Solutions of hydrogen fluoride gas in mucous fluids form highly corrosive hydrofluoric acid so that inhalation of decomposition products can cause symptoms of choking, coughing and severe eye, nose and throat irritation. After a symptomless period of 1-2 days, exposed individuals may experience a set of symptoms described as "polymer fume fever"; this is a temporary flu-like illness with fever, chills and, sometimes, a cough and difficult breathing which lasts for approximately 24 hours.  Inhalation or skin contact with carbonyl fluoride vapour may cause irritation with discomfort and rash. In addition, carbonyl fluoride vapours may produce eye corrosion with corneal and conjunctival ulceration, nose and throat irritation, or temporary irritation of the lungs producing cough discomfort, difficult breathing and shortness of breath.  Individuals with pre-existing lung diseases may have increased susceptibility to the toxic effects of thermal decomposition products.  

CHRONIC HEALTH EFFECTS

  There has been some concern that this material can cause cancer or mutations but there is not enough data to make an assessment.  There is limited evidence that, skin contact with this product is more likely to cause a sensitization reaction in some persons compared to the general population.  Propylene glycol is though, by some, to be a sensitizing principal following the regular use of topical creams by eczema patients. A study of 866 persons using a formulation containing propylene glycol in a patch test indicated that propylene glycol caused primary irritation in 16% of exposed individuals probably caused by dehydration. Undiluted propylene glycol was tested on 1556 persons in a 24 hour patch test. 12.5% showed reactions which were largely toxic (70%) or allergic in nature (30%). Reaction responses reached their maximum on the second day or later. Reactions were seasonal in nature ranging from 17.8% in winter to 9.2% in other seasons. In a patch-test using 25 standard allergens conducted on 500 individuals, propylene glycol ranked fourth in sensitizing response. 84 subjects were patch tested using 100% propylene glycol. as well as 2% and 5% in water. With undiluted material, 15% demonstrated a reaction, with 40% of the reactions being allergic in nature and 60% being irritant. In dilute solutions 5 of 248 subjects exhibited a reaction.  Undiluted propylene glycol tested on the skin of man produced no irritation under open conditions but when applied under occlusive conditions, for 2 weeks, it produced severe erythema, edema and vesicles, probably due to sweat retention and weak primary irritation.  Predictive contact skin sensitization tests indicate that propylene glycol is an intermediate grade sensitizer with an index of 1% of tested subjects.  Groups of cats fed 5 gm/kg/day of propylene glycol for 14 weeks showed a significant dose-  related increase in red blood cell Heinz body formation without any marked signs of hemolytic anemia. The no-effect-level for cats without formation of Heinz bodies is 100-  500 ml/kg. There is no evidence of anemia or degenerative change. Groups of rats dosed orally with 0.5 or 10 mg/kg/day for 12 weeks had lowered food intake but no adverse effects on body weights. Erythrocytes were more fragile. Heinz bodies were not apparent.  
【温馨提示】 MSDS安全网为了能让广大网友得到更好的服务,杜绝不法人员盗用本站共享资源,最终决定隐藏部分核心资源内容,只供注册会员查看; 本站会员采用微信账号登录/免费注册机制,登录成功后即可免费查看和下载本站所有资源!谢谢支持! 微信账号登录 注意:微信账号登录成功后,若页面没有刷新,请按F5刷新本页面!
在线下载 UNASCO TEFLON FIBRE REINFORCED THREAD SEALING COMP. MSDS报告