VESUVIUS LED70651
Flammability | 0 | |
Toxicity | 0 | |
Body Contact | 1 | |
Reactivity | 0 | |
Chronic | 3 | |
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4 |
Dust from old, fired refractories may be more hazardous than new materials. Use
respiratory protection when rebuilding or demolishing old furnaces. A refractory mix used
as a heat containment lining for industrial furnaces and associated production units.
"formerly Plicast Altuff LWI-24"
Harmful: danger of serious damage to health by prolonged exposure through
inhalation.
The material has NOT been classified as "harmful by ingestion". This is because of the lack of corroborating animal or human evidence. The material may still be damaging to the health of the individual, following ingestion, especially where pre-existing organ (e.g. liver, kidney) damage is evident. Present definitions of harmful or toxic substances are generally based on doses producing mortality (death) rather than those producing morbidity (disease, ill-health). Gastrointestinal tract discomfort may produce nausea and vomiting. In an occupational setting however, unintentional ingestion is not thought to be cause for concern.
Although the material is not thought to be an irritant, direct contact with the eye may cause transient discomfort characterized by tearing or conjunctival redness (as with windburn). Slight abrasive damage may also result. The material may produce foreign body irritation in certain individuals.
Skin contact is not thought to have harmful health effects, however the material may still produce health damage following entry through wounds, lesions or abrasions. Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may produce systemic injury with harmful effects. Examine the skin prior to the use of the material and ensure that any external damage is suitably protected.
The material is not thought to produce adverse health effects or irritation of the respiratory tract (as classified using animal models). Nevertheless, good hygiene practice requires that exposure be kept to a minimum and that suitable control measures be used in an occupational setting. Used, fired refractory materials are potentially more harmful than new refractories. Silica containing materials when exposed to high temperatures maybe devitrified (i.e. converted or part converted to crystalline forms) - this may present a higher hazard if inhaled. Crystalline silicas are more likely to produce lung changes (fibrosis) and have a much lower occupational exposure levels (OELs) than non crystalline silicas. Exposure to fired refractories is more likely when repairing, rebuilding or demolishing old structures. Devitrified, after-service alkaline earth silicate (AES) wools and refractory ceramic fibres (RCF) insulation containing crystalline silica, show no adverse reactions in toxicity assays. CMS fibres heated to 1000 deg. C. for 2 weeks were not cytotoxic to macrophage-like cells at concentrations up to 320 ug/cm2. In the same test, samples of crystalline quartz were significantly active at 20 ug/cm2. These findings are consistent with IARC's evaluation, which states "Crystalline silica inhaled in the form of quartz or cristobalite from occupational sources is carcinogenic to humans (Group 1)" and additionally notes, in respect of devitrified wools and fibres that "carcinogenicity in humans was not detected in all industrial circumstances studied. Carcinogenicity may be dependent on inherent characteristics of the crystalline silica or on external factors affecting its biological activity or distribution of its polymorphs" (IARC Monograph Vol 68, 1997).
Harmful: danger of serious damage to health by prolonged exposure through inhalation.