Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME

WATTYL SIGMASHIELD 1200 BASE

NFPA

Flammability 1
Toxicity 2
Body Contact 2
Reactivity 1
Chronic 2
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4

PRODUCT USE

Base or Part A of a 2 pack. epoxy coating system. Requires that the two parts be mixed by
hand or mixer before use, in accordance with manufacturers directions. Mix only as much as
is required. Do not return the mixed material to the original containers. Application is
usually by airless spray atomisation. Used according to manufacturer' s directions. The
use of a quantity of material in an unventilated or confined space may result in increased
exposure and an irritating atmosphere developing. May also be applied by brush or roller
only for stripe coating and spot repair.

Section 2 - HAZARDS IDENTIFICATION

CANADIAN WHMIS SYMBOLS

EMERGENCY OVERVIEW

RISK

May cause SENSITIZATION by skin contact.
Irritating to eyes, respiratory system and skin.
May cause long- term adverse effects in the environment.
Toxic to aquatic organisms, may cause long- term adverse effects in the aquatic
environment.

POTENTIAL HEALTH EFFECTS

ACUTE HEALTH EFFECTS

SWALLOWED

  Accidental ingestion of the material may be damaging to the health of the individual.  

EYE

  There is evidence that material may produce eye irritation in some persons and produce eye damage 24 hours or more after instillation. Severe inflammation may be expected with pain. There may be damage to the cornea. Unless treatment is prompt and adequate there may be permanent loss of vision. Conjunctivitis can occur following repeated exposure.  

SKIN

  The material may cause moderate inflammation of the skin either following direct contact or after a delay of some time. Repeated exposure can cause contact dermatitis which is characterized by redness, swelling and blistering.  Skin contact is not thought to have harmful health effects, however the material may still produce health damage following entry through wounds, lesions or abrasions.  Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may produce systemic injury with harmful effects. Examine the skin prior to the use of the material and ensure that any external damage is suitably protected.  

INHALED

  If inhaled, this material can irritate the throat andlungs of some persons.  Inhalation hazard is increased at higher temperatures.  The material is not thought to produce either adverse health effects or irritation of the respiratory tract following inhalation (as classified using animal models). Nevertheless, adverse effects have been produced following exposure of animals by at least one other route and good hygiene practice requires that exposure be kept to a minimum and that suitable control measures be used in an occupational setting.  

CHRONIC HEALTH EFFECTS

  There has been some concern that this material can cause cancer or mutations but there is not enough data to make an assessment.  Asthma-like symptoms may continue for months or even years after exposure to the material ceases. This may be due to a non-allergenic condition known as reactive airways dysfunction syndrome (RADS) which can occur following exposure to high levels of highly irritating compound. Key criteria for the diagnosis of RADS include the absence of preceding respiratory disease, in a non-atopic individual, with abrupt onset of persistent asthma-like symptoms within minutes to hours of a documented exposure to the irritant. A reversible airflow pattern, on spirometry, with the presence of moderate to severe bronchial hyperreactivity on methacholine challenge testing and the lack of minimal lymphocytic inflammation, without eosinophilia, have also been included in the criteria for diagnosis of RADS. RADS (or asthma) following an irritating inhalation is an infrequent disorder with rates related to the concentration of and duration of exposure to the irritating substance. Industrial bronchitis, on the other hand, is a disorder that occurs as result of exposure due to high concentrations of irritating substance (often particulate in nature) and is completely reversible after exposure ceases. The disorder is characterised by dyspnea, cough and mucus production.  Limited evidence suggests that repeated or long-term occupational exposure may produce cumulative health effects involving organs or biochemical systems.  There is some evidence that inhaling this product is more likely to cause a sensitization reaction in some persons compared to the general population.  Skin contact with the material is more likely to cause a sensitization reaction in some persons compared to the general population.  The material may accumulate in the human body and progressively causetissue damage.  Respiratory sensitization may result in allergic/asthma like responses; from coughing and minor breathing difficulties to bronchitis with wheezing, gasping.  