WATTYL INTERMEDIATE BROWN OXIDE DISPERSION
Flammability | 1 | |
Toxicity | 2 | |
Body Contact | 2 | |
Reactivity | 0 | |
Chronic | 2 | |
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4 |
Used as a colourant in epoxy based products. · Material is mixed and used in accordance
with manufacturers directions.
epoxy, "colourant dispersion", additive, imtermediate
May cause SENSITIZATION by skin contact.
HARMFUL - May cause lung damage if swallowed.
Harmful by inhalation and in contact with skin.
Irritating to eyes and skin.
Toxic to aquatic organisms, may cause long- term adverse effects in the aquatic
environment.
Although ingestion is not thought to produce harmful effects, the material may still be damaging to the health of the individual following ingestion, especially where pre- existing organ (e.g. liver, kidney) damage is evident. Present definitions of harmful or toxic substances are generally based on doses producing mortality (death) rather than those producing morbidity (disease, ill-health). Gastrointestinal tract discomfort may produce nausea and vomiting. In an occupational setting however, ingestion of insignificant quantities is not thought to be cause for concern. Considered an unlikely route of entry in commercial/industrial environments. Ingestion may result in nausea, abdominal irritation, pain and vomiting.
This material can cause eye irritation and damage in some persons. The material may produce moderate eye irritation leading to inflammation. Repeated or prolonged exposure to irritants may produce conjunctivitis.
Skin contact with the material may be harmful; systemic effects may resultfollowing absorption. This material can cause inflammation of the skin oncontact in some persons. Epoxy materials may cause allergic and/or contact dermatitis responses, which may occur on exposure or may become apparent only after repeated exposures. Sensitization is possible. Photoallergic dermatitis may result from contact with the material. This type of response can be elicited only in individuals who have been previously allergically sensitized to the chemical agent and appropriate radiation. Photoallergic dermatitis presents, clinically, as an eczematous dermatitis in sun-exposed areas. The material may accentuate any pre-existing dermatitis condition. Open cuts, abraded or irritated skin should not be exposed to this material. The material may cause skin irritation after prolonged or repeated exposure and may produce on contact skin redness, swelling, the production of vesicles, scaling and thickening of the skin.
The material is not thought to produce respiratory irritation (as classified using animal models). Nevertheless inhalation of the material, especially for prolonged periods, may produce respiratory discomfort and occasionally, distress. Inhalation hazard is increased at higher temperatures. Inhalation of vapor may result in nausea, headache.
Skin contact with the material is more likely to cause a sensitization reaction in some persons compared to the general population.
Principal routes of exposure are usually by skin contact/eye contact with the material and inhalation of vapor from heated material. Prolonged or repeated skin contact may cause drying with cracking,irritation and possible dermatitis following. Sensitization reactions may appear suddenly after repeatedsymptom free exposures. One ingredient of the product has caused skin sensitization reactions, shown as localized reddening and hives, or may produce respiratory sensitization characterized by asthma- like symptoms and runny nose.