WATTYL EPINAMEL SEALCOAT PART A
Flammability | 1 | |
Toxicity | 2 | |
Body Contact | 2 | |
Reactivity | 1 | |
Chronic | 2 | |
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4 |
Part A or Base of a 2 pack epoxy coating system. Apply by brush, hand roller or spray
atomisation. Requires that the two parts be mixed by hand or mixer before use, in
accordance with manufacturers directions. Mix only as much as is required. Do not return
the mixed material to the original containers. The use of a quantity of material in an
unventilated or confined space may result in increased exposure and an irritating
atmosphere developing.Before starting consider control of exposure by mechanical
ventilation.
"modified epoxy resin sealer coating base two-pack"
May cause SENSITIZATION by skin contact.
Harmful by inhalation, in contact with skin and if swallowed.
Irritating to eyes and skin.
Toxic to aquatic organisms, may cause long- term adverse effects in the aquatic
environment.
Accidental ingestion of the material may be harmful; animal experiments indicate that ingestion of less than 150 gram may be fatal or may produce serious damage to the health of the individual. Considered an unlikely route of entry in commercial/industrial environments. Ingestion may result in nausea, abdominal irritation, pain and vomiting.
This material can cause eye irritation and damage in some persons. The material may produce moderate eye irritation leading to inflammation. Repeated or prolonged exposure to irritants may produce conjunctivitis.
Skin contact with the material may be harmful; systemic effects may resultfollowing absorption. This material can cause inflammation of the skin oncontact in some persons. The material may cause skin irritation after prolonged or repeated exposure and may produce on contact skin redness, swelling, the production of vesicles, scaling and thickening of the skin. Open cuts, abraded or irritated skin should not be exposed to this material. Epoxy materials may cause allergic and/or contact dermatitis responses, which may occur on exposure or may become apparent only after repeated exposures. Sensitization is possible. Photoallergic dermatitis may result from contact with the material. This type of response can be elicited only in individuals who have been previously allergically sensitized to the chemical agent and appropriate radiation. Photoallergic dermatitis presents, clinically, as an eczematous dermatitis in sun-exposed areas. The material may accentuate any pre-existing dermatitis condition.
The material is not thought to produce respiratory irritation (as classified using animal models). Nevertheless inhalation of the material, especially for prolonged periods, may produce respiratory discomfort and occasionally, distress. Not normally a hazard due to non-volatile nature of product. Inhalation hazard is increased at higher temperatures.
Skin contact with the material is more likely to cause a sensitization reaction in some persons compared to the general population.
Principal routes of exposure are usually by skin contact with the material, inhalation of vapor/spray mist and inhalation of vapor from the curing material. Prolonged or continuous skin contact with the liquid may cause defatting with drying, cracking, irritation and dermatitis following. Sensitization reactions may appear suddenly after repeatedsymptom free exposures. Sensitization may give severe responses to very low levels of exposure, i.e. hypersensitivity. Sensitized persons should not be allowed to work in situations where exposure may occur. As with any chemical product, contact with unprotected bare skin; inhalation of vapor, mist or dust in work place atmosphere; or ingestion in any form, should be avoided by observing good occupational work practice.